Leuze Supplies Sensors For Multivac Thermoformer
Sensors of safety-class IP 69K only satisfy requirements for splashed-water applications without chemical additives such as acids or bases. A Henkel-Ecolab-Test FandE No 40-1 also includes the submersion of the sensors in cleaning agents for several weeks. Leuze Electronic's Cleanproof+ extends the tests with additional substances and performs the tests under more demanding conditions, for example at elevated temperatures.
These Wash-Down sensors can be mounted in the same way as traditional devices with attachment holes designed for M4 threads. The cable or plug connection is also comparable to the standard design but can be disinfected and is sealed against diffusion.