Accurate Pipettes Ensure Reproducible Research

Every researcher relies on accurate and reproducible results to publish research results in renowned journals. Pipette accuracy checks reduce errors, but they are also time-consuming and resource intensive. Choosing a balance that can easily be converted for quick pipette accuracy checks helps to assure the reproducibility of results.

Every researcher needs accurate, reliable and reproducible results to publish their research in renowned magazines. Global standards such as GLP and ISO 8655-6 require pipette testing at defined intervals to ensure their proper functioning. However, in between these periodic checks, researchers typically have little security that their pipettes are functioning properly.

Easy Checks for Repeatability
Pipette accuracy checks reduce errors, but they are also time-consuming and resource intensive. Now, convertible semi-micro balances such as the METTLER TOLEDO NewClassic MS combine standard weighing and pipette accuracy checks in the same easy-to-use laboratory balance for reliable—and reproducible—results.

A Stand Alone Solution
The NewClassic MS105 converts easily from a laboratory balance with 0.01 mg readability into a stand-alone pipette check-station. Firmware guides users through the check process. An evaporation trap is the only external device needed, if the pipetting volume is smaller than 100 μg. The trap keeps humidity levels stable during the check and thus minimizes evaporation for accurate testing.

Automatic Calculation
Distilled water is pipetted onto the balance and converted to a volumetric value. Proprietary embedded MS105 firmware automatically calculates systematic and random pipetting error in absolute and relative values. Results are displayed and can be printed for traceability or for a easy and quick comparison with the manufacturer’s tolerances

Maintaining Academic Accuracy
Convertible laboratory balances such as the NewClassic MS are ideal for use in the life sciences and other research areas requiring absolute surety when publishing results. By performing more frequent pipette checks than the periodic required ISO standard calibrations, researchers gain added security that pipettes are still performing as expected.

Innovative Products for Academic Research
METTLER TOLEDO offers a broad portfolio of high performance laboratory instruments for the academic world. Innovative RAININ pipettes such as the XLS Lite enhance lab performance, and minimize fatigue and injuries. Laboratory balances from the Excellence and NewClassic lines cover all weighing needs, from high performance weighing and One Click™ solutions to basic weighing with smart operation.

Comments

Popular posts from this blog

What is Class I Division 2?

FUSE SIZING CONSIDERATIONS FOR HIGHER EFFICIENCY MOTORS

7/8 16UN Connectors that Provide 600 Volts and 15 Amps